Power Meters & Modules
AcuRev 2100 Series
-
Multi-channel integrated electricity meter, 2-year warranty
-
Simultaneously measure 6 groups of three-phase,18 groups of single-phase power grids
★ANSI C12.20 class 0.5, IEC 62053-22 class 0.5s
★Measure 6, 9 or 18 single-phase multi-phase circuits simultaneously
★Modbus-RTU Protocol
★Optional BACnet, WiFi and dual Ethernet
★SnapOn CT technology reduces polarity errors and installation Maintenance time
★31st order odd harmonics
★Support TOU
L - L:10 to 690V, L - N: 57 to 400V
Current:1A / 5A / 333mV / Rogowski coil
Frequency:45-65Hz
Power supply:100~415Vac; 100~300Vdc
WEB2 version:supports 8GB memory, dual Ethernet ports, WiFi, BACnet-MS/TP
-
Built-in LCD display, 18DI / 6 DO / 2 RO & 8MB memory
ACUVIM lll Series
★Complies with IEC 61000-4-30 Class A standard and is certified by the third-party NMi
★Achieves industry-leading ANSI C12.20 Class 0.1/IEC 62053-2 Class 0.1S measurement accuracy, capable of precisely detecting power quality anomalies in critical distributed energy systems
-
ANSI C12.20/IEC 62053-22 Class 0.1 accuracy
-
Complies with IEC 61000-4-30 Class A standard for power quality monitoring
-
Complies with IEC 61000-4-15 standard for flicker measurement, used for voltage fluctuations
-
Waveform capture detects up to 512 samples per cycle and stores data in COMTRADE format
-
Frequency deviation triggers high-speed data recording events, including active power and frequency records before and after the event
-
Complies with EN50160/IEEE519 standards for power quality reporting
-
Complies with IEEE C37.118 standard for synchrophasor measurement and data transmission
-
Supports time synchronization via IRIG-B, NTP, SNTP and PTP
-
Multi-protocol communication: IEC 61850, EtherNet/IP, Modbus-RTU, Modbus-TCP/IP, BACnet-IP, BACnet MS/TP, DNP3 TCP, SNMP and IPv6/IPv4
-
Dual Ethernet ports, RS485, Wi-Fi (2.4GHz), IRIG-B, 4 digital I/O and USB-C interface
-
32GB data recorder and storage: Up to 15 configurable data recorders, supports user-selectable recording interval and parameters
-
Supports time-of-use (TOU) pricing, with 8 rate schedules and up to 12 historical billing periods
-
Optional 7-inch HMI touchscreen color remote display unit
-
5A/1A, 333mV or RCT (Rogowski) current sensor inputs
-
DIN rail or panel mount
ACUVIM II Series V3
With UL certification, 2-year warranty
★ANSI C12.20 class 0.1, IEC 62053-22 class 0.1s
★Accuracy level 0.1%
★High Resolution Frequency Measurements - 0.001Hz
★High Speed update rate - less than 20ms
★4th CT input - Measure Neutral Current
★Dual Ethernet Ports with both RSTP bridge daisy-chain mode & separately configurable network
★BTL Listed certification for BACnet IP and BACnet MS / TP
★63rd order odd harmonic (50Hz / 60Hz), 15th order Odd harmonics (400Hz)
TOU:4 Tariffs, 12 Seasons,14 Schedules
L - L:10 to 690V
L - N:57 to 400V
Current:1A / 5A / 333mV / 80mA / 100mA /
200mA / Rogowski coil
Frequency:45-65Hz
Power supply:100~415Vac, 100~300Vdc
DI / DO / AI / AO / RO / 24VDC output / RS485 / Ethernet / Profibus BACnet / WiFi / Fiber optic comm. / 4GB or 8GB memory / HTTP / ftp / SMTP / 868Mz or 900Hz wireless comm. are availabe on demand via extension modules.
-
Built-in 8MB (IIR) or 16MB (IIW) memory
-
Waveform acquisition/power quality event recording
-
Can be retrofitted with 400Hz detection module
-
Built-in Modbus-RTU Protocol, BACnet-MS/TP
-
IP56
ACUVIM-L Series V4
-
Accuracy level Class 0.2%
-
With UL certification, 2-year warranty
★ANSI C12.20 class 0.2,IEC62053-22 class 0.2s
★Accuracy level 0.2%(EL) / 0.5%(CL)
★4th CT input – measure neutral current
★Remote channel mapping and four channel multi-circuit metering
★Dual source meter to monitor energy usage from separate energy sources
★Dual Ethernet ports with both RSTP bridge daisychain mode and separately configurable network with AXM-WEB2
module
★63rd order odd harmonic (EL), 31st order odd harmonic (CL)
TOU:4 Tariffs, 12 Seasons, 14 Schedules
L - L:10 to 690V
L - N:57 to 400V
Current:1A / 5A / 333mV / 80mA / 100mA /
200mA / Rogowski coil
Frequency:45-65Hz
Power supply:100~415Vac, 100~300Vdc
DI / DO / RO / Data Logging / RS485(Group 2) / Ethernet / Profibus, BACnet / 4GB or 8GB memory / HTTP / ftp / SMTP are availabe on demand via extension modules.
-
Built-in 8MB memory, Modbus-RTU Protocol
-
IP56
Current Transformers
AcuRev 1310 Series
Support TOU, with UL certification, 2-year warranty
★ANSI C12.20 class 0.5, IEC 62053-22 class 0.5s
★Measure neutral current (1314 version)
★Calculate residual current (1314 version)
L - L:10 to 690V,L - N: 57 to 400V
Current:1A / 5A / 333mV / 80mA / 100mA /
Rogowski coil
Frequency:45-65Hz
Power supply:100~415Vac, 100~300Vdc
-
Power factor / Tangent φ
-
Built-in LCD display, Modbus-RTU,Protocol, BACnet-MS/TP
-
Built-in set of Relay output
-
IP56
ACUVIM-II Series Communication Modules
WEB2-FOLC:IEC 61850、Modbus-TCP、HTTP/HTTPs Webserver SMTP Email、SNMP、HTTP/HTTPs Push、FTP Post sFTP Server、BACnet-IP、Datalogging、WiFi、
Fiber Optics LC
WEB2:IEC 61850、Modbus-TCP、HTTP/HTTPs Webserver SMTP Email、 SNMP、HTTP/HTTPs Push、FTP Post sFTP Server, BACnet-IP, Datalogging, WiFi
WEB-PUSH: Modbus-TCP、HTTP/HTTPs Webserver、SMTP Email、SNMP、HTTP/HTTPs Push、FTP Post、sFTP Server、Datalogging
PROFI: PROFIBUS
RS485: Modbus-RTU
MESH-900: Wireless Radio (900MHz)
MESH-868: Wireless Radio (868MHz)
DC Power Meters / Current Sensors
AcuDC 240 Series
Charging pile / dedicated for energy storage, with UL certification
Current:Direct measurement 0...±10A,Shunt 50...100mV,Hall Effect Sensor,
0...±5V/0...±4V,4...20mA/12mA±8mA
Power supply:100...240Vac, 100...300Vdc or 20...60Vdc
Dimensions:72.0 x 72.0 x 64.5mm
Voltage:0...1000V
Accuracy:0.2%
-
Panel installation, optional aluminum rail installation accessories
-
IP56
-
Built-in LCD display screen
-
Optional Modbus-RTU Protocol
-
Optional Expandable I/O modules