top of page
General catalog 2019-01.jpg

Since 1954 Lumel brand has been known as a producer of top quality measuring devices and high-pressure die-castings all over the world.
Our high position in the market has been achieved thanks to continuous development policy, competence of our employees and modern technology in the areas of research, design and production.
We deliver complex solutions for power and industrial automation sector as well as for automobile, chemical, steel, or HVAC industries.

資產 3.png

Power network meters and analyzers

集合是
ND30.png

  ND30BAC

  • 57.7V (L-N) / 100V (L-L) or 110V (L-N) / 190V (L0L) or 230V (L-N) / 400V (L-L) or 400V (L-N) / 690 V (L-L)

  • 1A / 5A

  • 2 x Relay output

  • RS-485 Modbus Slave

  • BACnet IP

  • 3.5” colour TFT LCD  320x240 pixel

  • IP65

ND30.png
CloudReady.png

  ND30
  ND30IoT

  • 63rd order odd harmonic, full color TFT LCD display

  • Built-in 8GB memory for data logging

L - L:100 to 690V
L - N: 57 to 400V
Current:1A/5A
Frequency:45-65Hz
Power supply:85...253VAC or 90...300VDC

  • Accuracy level 0.2S (IEC 62053-22)

  • THD, 63rd order odd harmonics

  • Built-in RTC, Web Server supports remote login

  • Support RS485 Modbus RTU, Ethernet communica tion port, MODBUS TCP/IP, HTTP, FTP, MQTT / Relay output x 2 

  • Optional Pt100 or DI input x2, 4-20mA output x1

  • Optional PROFITNET or BACnet Version

NR10.png

  NR10

  • 176 to 276V (L-N) Single Phase

  • 0.5 to 10(100)A

  • Relay output

  • PWM output (OC type)

  • RS485 Output for Modbus RTU

  • DIN Rail Mount

NMID30_1.png
NMID30_2.png
MID.jpg

NMID30-1 / 2 Three-phase VAR hour meter

Built-in 100A CT, effectively saving space and cost.

Line voltage:173 to 500V

Phase voltage:100 to 289V

Current:1A / 5A or built-in 100A CT Frequency:45-65Hz

Power supply:87...275VAC ±10% or 120....380VDC ±20%

<Power Factor>

Forward / Reverse / Total Active Power:

0 to 9999999.9 kWh

Forward / Reverse / Total Reactive Power:

0 to 9999999.9 kVArh

  • Supports RS485 Modbus RTU, two sets of PWM outputs

 

ND30.png

  ND30PNET

  • 57.7V (L-N) / 100V (L-L) or110V (L-N) / 190V (L0L) or 230V (L-N) / 400V (L-L) or 400V (L-N) / 690 V (L-L)

  • 1A / 5A

  • 2 x Pt100 input - option

  • 2 x Relay output

  • 1 x 0/4...20 mA output (option)

  • RS-485 Modbus Slave

  • Ethernet ICMP (Ping

      Profinet ver. 2.2

  • 3.5” colour TFT LCD 320x240 pixel

  • IP65

ND25_web1.png

ND25 Power Meter

Directly replace PM5350
L - L:100 to 600V
L - N:57.5 to 346.42V
Current:1A/5A
Frequency:45-66Hz
Power supply:100-550VAC / VDC

  • Accuracy class 0.2S (IEC 62053-22)

  • THD, 31st odd harmonics

  • Built-in RTC

  • Support RS485 Modbus RTU, PWM output x 2

  • Optional 8MB memory for data recording

  • Optional Ethernet Version

ND20.png

  ND20

  • 57.7V (L-N) / 100V (L-L) or 

      63.5V (L-N) / 110V (L-L) or

      69.3V (L-N) / 120V (L-L) or
      230V (L-N) / 400V (L-L) or  

      290V (L-N) / 500V (L-L)

  • 1A / 5A

  • 1 x 0/4...20 mA, 1 x relay,1 x pulse output

  • RS-485 Modbus Slave

  • 3.5” LCD, 3 x 4 (11 mm) + 1 x 5 digits (9mm)

  • IP65

ND20Lite.png

ND20LITE Power Meter

Cost Effective Solution
L - L:100 to 400V
L - N:57 to 230V
Current:1A/5A
Frequency:47-63Hz
Power supply:85...253VAC or 20...40VDC

  • THD

  • 0.5 Class high accuracy

  • Support RS485 Modbus RTU,

  • Relay output x 1 / PWM output x 1

資產 34_3x.png

ND45

  • Class A ultra-high accuracy

  • Frequency measurement error can reach ±0.010 Hz

Comply with IEC EN 50160 and IEC 61000-4-30 standards
Record measurement values ​​before and after dips and surges
Supports IEC 60870-5-104 communication protocol (optional)
Supports external GPS module - STR receiver for time synchronization (Optional) 
Voltage:69.3 / 120V, 57.7 / 100V or 230 / 400V
Current:1A / 5A
Frequency:42.5-69Hz

  • Measure more than 500 power quality parameters,4 quadrants of electricity

  • Record measurement values ​​before and after the event occurs,Monitor 6 external meters through PWM output

  • 5.6” full-color TFT touch screen

  • Built-in RTC, supports synchronization with time server

  • Supports up to 32GB SD card for data  recording,RS485 Modbus RTU,Ethernet and USB2.0 communication port, Modbus TCP/IP,Web server, FTP Server, DHCP client

  • Optional input-Pt100 / Pt1000, binary

  • Optional output-binary, analog, Relay

資產 35_3x.png

NS5

Designed for applications where 
generators are connected to the
gridVoltage:50...150V or 150...400V
Voltage difference:δU -20..0..20%
Frequency:45-65Hz
Frequency difference:δf -10..0..10 %
Phase shift:φ0..360°
Power supply:85...253VAC or 90...300VDC

  • Two sets of control signals 20...250VAC/DC

  • Lock synchronization x 1, start synchroniza tion x 1

  • Two sets of NO contact outputs

  • 0.2 Class high accuracy

  • 3.5” full color TFT screen

  • Support RS485 Modbus RTU,Ethernet communication port, Web server, 

      Modbus TCP / IP、DHCP server 

資產 36_3x.png

NF20

Designed for capacitor bank applications Voltage: 30 to 550VAC (L-L / L-N)

Current: 1A / 5A

Frequency: 40-70Hz

Power supply: 110 to 550 VAC/DC

  • 31 odd-order harmonic steps

  • Four-quadrant operation of capacitors

  • 0.5 Class high accuracy

  • Monitors power values of individual capacitors

  • Programmable connection / disconnection     and discharge times, independent kvar value for capacitor banks

  • Supports 4, 6, or 8 relay outputs, RS485 Modbus RTU

N27P_web.png

  N27P 1-phase Power Meter

  • OLED display

  • Built-in RS485 MODBUS RTU, OLED graphic display

Parameter settings can be performed through free eCon software (via USB
Voltage:0...100/400VAC
Current:1A/5A via CT or 63A direct measurement
Output:Relay output x 2 or Relay x1 + 
4...20mA x 1 outputs

External dimensions:53 x 110 x 60mm

NR32.png

NR32 Power Meter

31st order odd harmonics

★Measure the KWh of each phase 
  independently
Measuring voltage:
100VLL to 600VLL
(57.7VLN to 346.4VLN)

Current input:1A/5A
Power supply:100V to 550VAC/DC
Frequency:47-66Hz

  • Support RS485 Modbus RTU

  • Accuracy level 0.2S (IEC 62053-22) 

229.png

SPC5 Reverse power controller

  • Special for solar power grid, can control inverter output

  • For three-phase four-wire power grid

Dual RS485 communication port (Master+ Slave)
Measured voltage:1
00VLL to 600VLL (57.7VLN to 346.4VLN)
Current input:1A / 5A
Power supply:100V to 550VAC / DC
Operating temperature:-20 to +70 °C

  • Display the power flow between the inverter, grid and load

  • Accuracy Class 0.2S (IEC 62053-22)

N43.png

N43 Power Meter

L - L:173 to 500V
L - N:100 to 289V
Current:1A/5A or built-in 63A CT
Frequency:47-63Hz
Power supply:85...253VAC or 20...40VDC

  • Built-in Relay output x 3, PWM output x 1

  • Support RS485 Modbus RTU

NR30Iot_web.png

NR30IoT Power Meter

  • 63rd order odd harmonic, built-in 63A CT

  • Built-in 8GB memory for data logging function

L - L:100 to 690V
L - N:57 to 400V
Current:1A/5A or built-in 63A CT
Frequency:45-65Hz
Power supply:85...253VAC or 90...300VDC

  • Support RS485 Modbus RTU, Ethernet communication port, MODBUS TCP/IP, HTTP, FTP, MQTT, Relay output x 2

  • Accuracy level 0.2S (IEC 62053-22)

  • THD, 63rd order odd harmonics

  • 0.2 Class high accuracy

  • Built-in RTC

  • Optional PROFITNET or BACnet Version

數位顯示器

Digital Meters

N24web.png

N24 Digital Display

Power: 85 ... 253 V a.c./d.c.

Protection level: IP65

<Input Signal>

N24S: 0-20mA / 4-20mA / ± 20mA ± 60 mV / 0-10 V / ±10 V

N24T: Pt100 -50-150°C / -50-400°C Thermocouple J / K

N24Z: 0-100 / 0-250 / 0-400VAC, 0-1A / 0-5A AC

Frequency: 20-500 Hz

N24H: ±100 / 250 / 400VDC, 0-100/200VDC, ± 1 / 5 A d.c.

  • 4-digit LED display

  • Parameters can be set via PD14 programmer and free eCon software download

  • Automatically or manually compensates for cold junction temperature or wire resistance measured by Pt100 sensor

N25web.png

N25 Digital Display

Power: 85 ... 253 V a.c./d.c.

Protection level: IP65

<Input Signal>

N25S:0-20mA / 4-20mA / ± 20mA ± 60 mV / 0-10 V / ±10 V

N25T: Pt100 -50-150°C / -50-400°C Thermocouple J / K

N25Z:0-100 / 0-250 / 0-400VAC, 0-1A / 0-5A AC

Frequency: 20-500 Hz

N25H: ±100 / 250 / 400VDC, 0-100/200VDC, ± 1 / 5 A d.c.

  • 5-digit LED display

  • Parameters can be set via PD14 programmer and free eCon software download

  •  Automatically or manually compensates for cold junction temperature or wire resistance measured by Pt100 sensor

N30Hweb.png
N30Uweb.png

N30x multi-function monitor

Three-color LED, RS485, 4 groups of alarms, can be used as secondary output
<Input signal>
N30H:
DC ±100V/500V, ±1/5A
N30P: AC 0-1A/5A, 0-100/400V
N30U:Pt100, Pt500, Pt1000, J, K, N, E, R, S,
0-400Ω, 0-4kΩ, ±60mV, ±10V, ±20mA
N30Opulse wave -10kHz/8kHz,encoder-10kHz
frequency -100kHz/1MkHz,Speed-100kHz, 
<Optional output>

-RS485 MODBUS RTU

- 0/4-20mA x 1 & 0-10VDC x 1

- OC type NPN (N30P)

- 24VDC/30mA power output (N30U/N30O)

Power supply:85-253VAC/DC, 20-40VAC/DC

  • Alarm output:2 NO relays and 2 CO relay outputs

  • 3-color LED red/orange/green (5 digits, character height 14mm), Different intervals can be distinguished, and the values ​​are displayed in different colors.

  • Support RS485 MODBUS RTU

  • Front panel IP65 protection

N32H_web.png

N32x multi-function display

High contrast LCD, RS485, 4 groups of alarms, can be used as secondary output

<Input signal>
N32H:
DC ±50...±600V, ±75...±1500mV
N32P:AC 0-1A/5A, 0-100/230/400V
N32U:Pt100, Pt500, Pt1000, J, K, N, E, R, S
0-400Ω, 0-4kΩ, ±60/150/300mV, ±10V,
±20mA, 4...20mA
N32O:pulse wave -10kHz/8kHz, encoder-10kHz
frequency -100kHz/1MkHz,Speed-100kHz
<Optional output>
- 0/4-20mA x 1 & 0-10VDC x 1
- OC type NPN (N30P/N30H)
- 24VDC/30mA power output (N30U/N30O)
Power supply:85-253 VAC/DC, 20-40 VAC/DC
Alarm output:1 NO relay, 3 CO relay outputs

  • High contrast and built-in backlight two-line LCD display that can be used simultaneously display measured value, time, uncalculated quantity, unit

  • Front panel IP65 protection

N21_poziom-i-pion_web1.png

N21 strip display

Can be displayed horizontally or vertically
Voltage input:
±75mV/±10V
Current input:±20mA
Pt100:-200 to 850°C
Thermocouple J:-50 to 1200°C
Thermocouple K:-50 to 1370°C
Power supply voltage:24-230VAC/DC

  • Provide 24VDC power supply to the sensor

  • A set of alarm outputs

  • OLED strip graphic display(horizontal or vertical)

  • Front panel IP65 protection

NA5,6-PLUS_web-1.png

NA5PLUS / NA6PLUS digital display

High-end graphic display with mathematical operation function
<Programmable input>
Voltage:
0-600V/±75mV, ±300mV
Current:±40mA/±5A
<temperature>
RTD:
Pt100/Pt500/Pt1000
TC:J/K/N/E/R/S/T
Resistance:0-10kΩ
<Analog output>
- 0/4-20mA x 2
- 0-10VDC x 2
- 0/4-20mA x 1
- 0-10VDC x 1

Optional output 4 relays or 8 OC type outputs
Power supply:
95-230VAC/DC or 20-24VAC/DC
NA5PLUS:1 set of input, 1 set of bar graph 
and Digital Display
NA6PLUS:2 sets of inputs, 2 sets of bar graphs 
and Digital Display

  • Multi-color bar graphic programmable display

  • Support RS485 MODBUS RTU

訊號傳送器
P10_web.png

P10

Input: 4...20 mA, 0...1/5/20/100 mA, d.c.0...60/75/100/500 mV, d.c.0...1/5/10/150 V d.c.

Output: 0/4...20 mA or 0/2...10 V

  • IP40

 Transducer

P10Z_web.png

P10Z

Input:1/5 A a.c., 0...100/250/ 300 V a.c.

Output:0/2...10 mA or​ 0/4...20 mA or

 0...10 V or 0...5 V

  • IP40

P15_web.png

P15

Input:0/4...20 mA, 1...5 mA

Output:2 x 0/4...20 mA

  • IP40

P17_web.png

P17

Input:Pt100, J, K, N, E, 0...10 V, 0...60 mV

Output: passive 0/4...20 mA

  • IP40

P17G 0/4-20mA Separators

Input: 0/4...20 mA

Output: active output 0/4...20 mA

  • IP40

P20_web.png

P20

Input: programmablPt100/250/500

1000, J, K, S, N,0/4...20, ±20 mA, 0...5/10,
±5, ±10 V, ±60, ±150 mV,
0...400Ω/4000Ω

Output: 0/4...20 mA or 0...10 V

  • IP40

  • free eCon software (using PD14

      programmer)

P20G_web.png

P20G

Input: programmable 0/4...20 mA,±20 mA, 0...5/10 V, ±5V, ±10 V

Output:programmable -20...20 mA,10...10 V

  • IP40

  • free eCon software (using PD14

      programmer)

P20H_web.png

P20H

Input: fixed 100, 250, 400 V d.c.,  ±100, ±250,±400 V d.c.,±1, ±5 A d.c.

Output:0/4...20 mA or 0...10 V or RS-485

Modbus Slave

  • IP40

  • free eCon software

      (using PD14 programmer)

P17G_web.png
P20Z_web.png

P20Z

Input: fixed 0..60/100/150/250/400/500

600 V a.c.0..1/5 A a.c

Output: 0/4...20 mA or 0...10 V

  • IP40

P21Z_web.png

P21Z

Input: fixed 0...100/250//400 V a.c.0...1/5 A a.c. , 20...500 Hz

Output: 0/4...20 mA or 0...10 V​ or RS-485 Modbus Slave

  • IP40

  • free eCon software- (using PD14

      programmer)

P30H_Ethernet_web.png

P30H

Suitable for charging pile / Energy storage
3-year warranty
Built-in:
LCD display screen, can display 8 characters x two lines
Voltage:0 ... 12 / 48 / 100 / 250V (direct measurement) / 0...600 / 1000V (via D5 high voltage module)
Current:Shunt +/- 150mV
Output:0/4…20mA x 1, Relay x 2
Power supply:85-253Vac/85-300Vdc
Dimensions:45 x 120 x 100mm

  • Accuracy 0.2%

  • Built-in RS485 Modbus-RTU Protocol, 4MB memory, can record 534336 pieces of data

  • Optional Ethernet Modbus TCP/IP, Support HTTP, FTP, Web server, ftp server, clientDHCP

  • Din rail installation

  • IP20 

P30O_ethernet_web.png

P30O

Input-2 programmable inputs:

pulse counter, frequency,rotational                speed, period, operating time counter,

pulse differential counter on inputs

or encoder 

Output: 1 x analog 0/4...20 mA or 0...10 V

1 x relay NO,1 x relay NO or 24V/30mA, 

output (optional output 2)

  • RS-485 Modbus (Slave or Master)

  • Ethernet 10/100 Base-T(option)

  • LCD 2x8 characters with backlight

  • IP40

  •  Alarms indicated on the display

  • Internal memory 534336 samples

  • WWW server, FTP, Modbus TCP/IP Slave (optionally)

  • Data logging in internal memory or

       on SD card (optionally)

P30P_ethernet_web.png

P30P

Input:1-phase power network,fixed 1A (X/1A), 5A (X/5A),100 V(x/100 V) or 250 V

Output:1 x analog 0/4...20 mA or 0...10 V,
1 x relay NO or  0/4...20 mA or0...10 V (optional output 2),1 x relay NO or 24V/30mA,output (optional output 3)

  • RS-485 Modbus (Slave or Master)

  • Ethernet 10/100 Base-T(option)

  • LCD 2x8 characters with backlight

  • IP40

  • Alarms indicated on the display

  • Internal memory 534336 samples

  • WWW server, FTP, Modbus TCP/IPSlave (optionally)

  • Data logging in internal memory or​ on SD card (optionally)

P30U_ethernet_-web.png

P30U

Input:programmable,Pt100/250/500/1000,
Cu100, Ni100, Ni1000,J, K, N, E, R, S, T, B
0...4/20, ±20 mA,-5...20, ±75, ±200 mV,
±10 V, ±24 V,400Ω, 2000Ω, 5500Ω,
RS-485 Master or Slave

Output: 1 x analog 0/4...20 mA or 0...10 V,
1 x relay NO,1 x relay NO or 24V/30mA ,

output (optional output 2)

  • RS-485 Modbus (Slave or Master)

  • Ethernet 10/100 Base-T(option)

  • LCD 2x8 characters with backlight

  • IP40

  • Alarms indicated on the display

  • Internal memory 534336 samples

  • WWW server, FTP, Modbus TCP/IPSlave (optionally)

  • Data logging in internal memory or on SD card (optionally)

T22CT_web.png
T23CT_web.png

T22CT / T23CT

AC/DC current converter
<T22CT AC current sensor>

Output:4...20mA or 0...20mA DC 
<Measurement range>
- 50...300A (T22CT-1)
- 150...750A (T22CT-2)
Supply voltage:24VDC
<T23CT AC / DC current sensor>
Supply voltage:24VDC
Measuring range:50A...300A
Output:4...20mA

  • Support DIN rail installation

P41_web.png

P41

Input: programmable 1-phase power 1/ 5 A , 100/ 400 V

Output:1 x analog programmable ±20 mA

  • RS-485 Modbus Slave

  P43

  • Input:fixed 3-phase power 1 or 5 A, 100 or 400 V

  • Output: 4 x relays or 2 x relay + 2 x analog programmable ±20 mA or

       4 x analog programmable ±20mA

  • RS-485 Modbus Slave

P43-web.png
ULS10.png

  ULS10 Ultrasonic level sensor

  • level and distance measurement in industrial conditions up to 10/15m

  • waterproof and dustproofhousing

  • standard galvanic separated​ analog output 0/4..20 mA 

  • RS-485 output

Temperature and Humidity Transducer

P18L_.png

P18L

Measurement range:-30 ... or 0...100% RH​ -20 ... 60 ... 85°C

Output: passive 4...20 mA

  • Supply Voltage: 19...30 VDC

      (supplied by a current loop)

  • IP65

P18S.png

18S temp. & humidity Transducer

Suitable for semiconductor equipment and 
environmental control applications 

Measuring range:-30°C to +80°C, 0 to 100% humidity
Output:RS485 Modbus RTU
Protection level:IP65

  • Temperature and humidity 2-in-1 sensor

  • Calculation of selected physical quantities (dew point temperature / absolute humidity)

  • Convert measured values ​​into output signals based on individual linear characteristics

  • Store the max and min ​​of measurement ​​and calculated values, and program measurement average time

P18-web.png
P18D.png

P18 / P18D temp. & humidity Transducer 

  • Suitable for applications such as machinery and equipment

  • The wires can be assembled according to the requirements before shipment

Measuring range:-40°C to +85°C, 0 to 100% humidity
Output:None, 0-10V x 2, 4-20mA x 2, RS485 Modbus RTU
Protection level:IP65

  • Temperature and humidity 2-in-1 sensor

  • Calculation of selected physical quantities (dew point temperature / absolute humidity)

  • Convert measured values ​​into output signals based on individual linear characteristics

  • Store the max and min ​​of measurement ​​and calculated values, and program measurement average time

ULT20.png
ULT21.png

ULT20/21 Ultrasonic Level Sensor

<Level Measurement Range>

ULT20: 0.5...8M

ULT21: 0.5...10M / 15M

Ultrasonic Frequency: 50KHz

Measurement Resolution: 0.001m, ±1% measurement range error

Power Supply: 24VDC

Analog Output: 0 / 4..20 mA

  • Supports RS-485 Modbus RTU

  • Built-in 2 alarm relay outputs, data setting memory

  • Automatic temperature compensation for calculating fill level in tanks or flow in open channels

  • IP66 or IP68 protection level

超音波
溫溼度傳送器
HT20.png

HT20

Measuring:temperature, relative humidity absolute humidity, dew point

Measurement range: -30 ... or 0...100% RH,

-20 ... 60 ... 85°C

Output: Modbus TCP/IP

Interface:Ethernet (WWW, FTP, SMTP, DHCP)

  • LCD, 2 x 16 characters

  • Supply Voltage:6 V d.c. or PoE IEEE 802.3af - option

  • Built-in 8GB internal memory

  • IP20

HT20IoT_web.png

HT20IoT

Measuring:temperature, relative humidity absolute humidity, dew point

Measurement range:-30 ... or 0...100% RH,

 -20 ... 60 ... 85°C

Output: Modbus TCP/IP

  • Interface:Ethernet (WWW, FTP, SMTP, DHCP) MQTT Protocol

  • LCD, 2 x 16 characters

  • Output: Modbus TCP/IP

  • Supply Voltage: 6 V d.c. or PoE IEEE 802.3af - option

  • Built-in 8GB internal memory

  • IP20

HT22IoT_web.png

HT22IoT environmental parameter monitor

​Suitable for greenhouses, clean rooms, laboratories...

Measuring range:-20°C to +60°C, 0 to 95% humidity 
Lux:0...60000lux
TVOC:0...60000ppb
CO2:400...60000ppm
<Measure, monitor and record the following environmental parameters>
- Temperature, humidity, illumination, CO2 concentration
- TVOC (total volatile organic compounds in the air)

  • Actively notify whether the measured value exceeds the limit range, and DO Alarm can be set for the selected input value

  • Built-in 8GB memory for data recording

  • Built-in RS-485 Modbus RTU, Ethernet 10/100 BASE-T

  • Support Modbus TCP/IP, HTTP, FTP, www, ftp, DHCP, SMTP, MQTT

  • Support RTC

資產 38_3x.png

KD6 Recorder

Compact Recorder
Input:Up to 8 sets of universal analog inputs, 8 sets of binary inputs
Output:up to 12 groups of relay outputs, 8 groups of analog outputs
Power supply:85...253VAC, 90...300VAC, 20...60VDC
Communication port:RS-485 MODBUS (master-slave), ETHERNET MODBUS TCP/IP, WWW, FTP, NTP, DHCP, USB Host 2.0
Dimensions:96 x 96 x 77mm

  • 3.5" TFT full color LCD display

  • Up to 60 logic channels

  • Up to 8 analog channels

  • Support 24Vd.c./30mA power output

  • Parameter setting and data transmission can be performed through the USB port

  • Built-in 8GB memory

  • Advanced mathematical function operations

Data Logger

KD7.png

KD7 Recorder

FDA certified full-featured recorder 3-year warranty

Communication Interfaces:RS-232, RS-485 (master-slave),USB, ETHERNET MODBUS TCP/IP, WWW/FTP Server
PC software:KD7 SETUP, KD CHECK, KD CONNECT, KD archive
Dimensions:144 x 144 x 155mm

  • Display curve charts, bar trend charts, pie charts, digital and analog indicators

  • Each channel can have settings assigned to color, name, range and presentation view

  • Support data statistics

  • 12 analog inputs (programmable and standard)

  • 5.7” LCD TFT touch panel

  • 6 or 32 Alarm outputs

  • 8 or 16 DIs

  • 4 or 8 analog outputs

  • Built-in 6MB memory

  • Data can be recorded on external CF card

  • Supports CF card with a maximum capacity of 4 GB

  • IP65 protection rating on front panel

  • Up to 24 measurement channels

  • MS Windows®CE operating system

KD8.png

KD8 Recorder

FDA certified economical recorder with
3-year warranty

Supports communication via: RS-485, USB MSWindows®CE operating system

PC software: KD7 SETUP, KD CHECK, KD CONNECT, KD ARCHIVE External dimensions: 144 x 144 x 155mm

  • 5.7" LCD TFT touch panel

  • Displays trend graphs, bar graphs, digital and analog indicators

  • Supports data statistics

  • Each channel can assign settings for color, name, range, and demo view

  • Built-in 6MB memory

  • Data can be recorded on external CF cards

  • Supports CF cards up to 4 GB capacity

  • IP65 protection level on front panel • Up to 6 measurement channels

  • 6 analog inputs (programmable and standard)

  • 6 or 12 alarm outputs

  • 8 or 16 DI

SM61IoT-web_cloud.png

SM61IoT

IoT data collector

  • Support MQTT protocol

  • Built-in WWW/FTP server, 8GB memory

  • Support RS232, RS485 Master, RS485 Slave,Modbus RTU, Ethernet

  • TCP, IP, Modbus TCP, www, ftp Server

  • 2 sets of relay outputs

資料紀錄器

Interface Converters / Gateways

資產 37_3x.png

PD9

RS485 to Ethernet interface converter

Communication port:RS485 x 1, 
Ethernet WAN / LAN x 1
Working mode:TCP / UDP Server & Client
Supply voltage:5...36VDC
Operating temp:-40 to 85°C

  • Easy settings via webpage or setting software

  • Miniaturized, DIN rail mounting design

  • Support Modbus RTU to TCP, Modbus Polling,DHCP, dynamic or static IP

  • Watchdog function

  • Firmware upgradeable via network

資產 31.png

PD9W

RS485 to WiFi interface converter

​Comm. protocol:Modbus RTU / Modbus TCP IP
Support:TCP Server, TCP Client, UDP Client,UDP Server
Comm. port:802.11b/g/n WiFi, RS485 x 1,
RS232 x 1, Ethernet WAN / LAN x 1
Working mode:TCP/UDP Server & Client
Electrostatic protection:15/8 kV
Power supply voltage:5...36V
Operating temp:-40 to 85°C

  • Easy settings via web page or setting software

  • Support DHCP support, dynamic or static IP

  • Support STA/AP/AP+STA mode

  • Support virtual COM Port

  • Watchdog function

PD20_web.png

PD20

USB to RS-485 interface converter

  • Compatible with standard USB 1.1 and USB 2.0

  • RS-485 maximum baud rate 115.2kbps

  • USB port maximum transfer rate up to 1Mb/s (depending on RS-485 cable length)

  • Support virtual COM Port

  • Bidirectional data transmission (half-duplex)

  • Designed with galvanic isolation protection and powered directly by USB

PD24.png

PD24

USB to RS-232(TTL) interface converter

  • Compatible with standard USB 1.1 and USB 2.0

  • RS-232 maximum baud rate 115.2kbps

  • Support virtual COM Port

  • Kit includes 1.5m profile with RJ12 plugTransmission line for setting up LUMEL products

  • Designed with galvanic isolation protection and powered directly by USB

Interface Converters / Gateways ​
溫度控制器

Temperature Controllers

資產 39_3x.png

RE11

European quality, domestic price, 3-year warranty

​<Accuracy>
J, K, T input:0.25% ± 1° of F.S.
R, S input:0.5% of F.S. ±2° (preheating time: 20 minutes)
RTD input:0.1% of F.S ±1°
Resolution:0.1/1° for TC/RTD (R and STC are fixed at 1°)
Control output:relay / SSR
Auxiliary output:relay
Control mode:automatic adjustment /

self-adjustment / PID / ON-OFF
Supply voltage:85 to 270VAC/VDC
Dimensions:52 x 52 x 76mm

  • 4 + 4 digit LED dual display

RE62.png

RE62

DIN rail installation, OLED display
Input:
NTC J, K, RTD Pt100, ±20mA,±60 mV, ±10V
Output optional:relay x 3, relay x 2 + SSR x 1,Relay x 2 + 4...20mA x 1
Universal power supply:22 V a.c./d.c. or 230 V a.c./d.c.
Dimensions:53 x 110 x 60.5mm

  • 128 * 64 pixel OLED display

  • Built-in RS485 MODBUS-RTU

  • Parameters can be set through eCon software

  • SMART PID algorithm

  • DIN rail installation

RE72.png

RE72

Input:programmable Pt100/1000,J, T, K, S, R, B, E, N, L or0/4...20 mA, 0...5/10 V

Additional Input:logic, CT Input, 0/4... 20 mA (option)

Output: 2 x relays, logic 0/5 V, 0/4...20mA,

0...10 V, supplying output,24 VDC / 30 mA (Option) 

Interface:RS-485 Modbus

  • On/Off , PID, heating or cooling

  • Red & Green LED 2 x 4 digits

  • Supply Voltage:85...253 V a.c./ d.or 

      20...40 V a.c./d.c

  • IP65

  • Soft start / 6 types of alarms /alarm LATCH function

RE82.png

RE82

Input:programmable Pt100/1000, J, T, K, S, R, B, E, N, L or 0/4...20 mA, 0...5/10 V

Additional Input: 2 x logic, CT Input, 

0/4... 20 mA (option)

Output: 2 x relays and 2 x relays,logic 0/5V, 0/4...20 mA, 0...10 V (option), supplying output 24 V d.c. 30 mA(option)

Interface:RS-485 Modbus

  • On/Off , PID, heating or cooling

  • Red & Green LED 2 x 4 digits 2 bargraphs

  • Supply Voltage:85...253 V a.c./ d.c or 20...40 V a.c./d.c

  • IP65

  • Soft start / 6 types of alarms /alarm LATCH function

RE92.png

RE92

Dual temperature control loops, dual communications, LCD display
Two sets of universal inputs:
RTD, TC, 0..5/10V, 0/4..20mA,
One set of 0/4..20mA or 0..5/10V input
<Output>
- 6 groups of relays or 4 groups of relays + 2 groups of SSR output
- 3 sets of binary outputs
- 1 set of 0/4-20mA x 1 or 0-10VDC output
Built-in:RS-485 Modbus RTU Master & Slave,Ethernet (MODBUS TCP Slave, FTP & Web server)
Power supply voltage:85...253VAC/DC
Dimensions:96 x 96 x 100mm

  • Double loop temperature controller

  • Can independently control two controlled objects or control two physical values ​​in one object

  • SMART PID algorithm with self-tuning function, on/off, three-stage control heating and cooling and step-by-step control, 320 x 240 pixel 3.5" LCD display, data logging function, support for .CSV files, SD memory card self-update and data saving

  • Parameters can be set through eCon software (via USB port)

輸入/輸出模組

I/O Modules

SM1-web.png
SM2-web.png

  SM1 / SM2

  • Input:Pt100(-200...850℃) , 0...400Ω,or 0/4...20 mA or 0...10 V

  • RS-485 Modbus Slave,

       RS-232 for configuration

  • SM1 2 input channels

  • SM2 2 input channels

SM3-web.png

SM3 digital input module

<Programmable input>
- logic on/off
- pulse counter
- up to 1 kHz
- 0...4,294,967,295 pulse waves
<Support>
RS485 MODBUS RTU & RS232 interface

  • 2 sets of logic or pulse inputs

  • Can be Confirgued by eCon software

SM4-web.png
SM5-web.png

SM4 / SM5 digital output module

SM4:8 OC outputs or 4 Relay outputs
SM5:8 digital inputs
<Support>
- RS-232 (RJ connector, for parameter setting)
- RS-485 MODBUS RTU & ASCII

  • Can be Confirgued by eCon software 

指針式錶頭
S4AI.png

S4AI analog input module

​​<4 programmable analog inputs>
±10 V, ± 20mA, Pt100, Pt500,Pt1000, J, k, S,
±150mV
<Support>
- RS-485 Modbus Salve
- Two programmable alarm outputs
- Mathematical functions: addition,

   subtraction,multiplication,division, average, 

   minimum,maximum

  • Two virtual measurement channels to 

  • perform mathematical functions on the 

  • channel or between measurement   

  • channels, programmable operating time 

  • counter

  • Parameter setting via USB port, no need

       to connect to the power supply

S4AO.png

S4AO analog output module

<4 sets of analog output>
- 4 x 0/4...20mA
- 4 x 0..10V
- 2 x 0/4...20mA
- 2 x 0...10V
Support:RS-485 Modbus Master & Salve
- Master Modbus function dedicated to read 
out data from other RS-485 devices and to scale analog value.
- Slave Modbus function to set the signal on 
analog outputs.

  • Output work time counter for values ​​above and below a certain threshold.

  • Parameter setting via USB port, no need to connect to the power supply

PD8-web.png

  PD8

  • RS-485 to Ethernet converter

  • Interface 1:RS-485, RS-232

  • Interface 2:Ethernet RJ45

  • Interface 3:USB

  • Support: Galvanic isolation Digi

      RealPort®, TCP/IP, HTTP, ICMP, DHCP, 

      ARP Modbus TCP

PD10-web.png

  PD10

  • RS-485 to USB converter

  • Interface 1:RS-485

  • Interface 2:USB

  • Support: Galvanic isolation

PD14_web.png

PD14

programmer to configure on RS-485 devices using eCon

eCon_1.jpg
eCon-ikonka.png

eCon

Free Software for Configuration of Lumel Products

 Analog Panel Meters

V_Meter.png
EP29-web.png
FA39-web.png
CA39-web.png
BE39-web.png
BA39-web.jpg
CA39L-web.png
FA39L-web.png
EA19D.png

Moving-iron meters

3 Phase Meters

Moving-Coil meters

Max demand ammeter

Power factor and

frequency meters

Dual Meters

比流

Current Transformer

LCTM ZIELONY.png

LCTM Series CT

<Measurement ranges>
LCTM 62/W type:
1...25A
LCTM 74/W type:1...60A
Accuracy Class:0.2, 0.5, 1

  • Secondary side optional 5A or 1A

  • IP20 protection board at the secondary side

  • Comply with CE regulations

  • High mechanical strength housing, made by special flame retardant materials

LCTS.png

LCTS compact Series Split Core CT

<Measurement ranges>
LCTS 50/18SC type:
100 250A
LCTs 50/32SC type:250 500A
Accuracy Class:1

  • Secondary side optional 5A or 1A

  • IP20 protection board at the secondary side

  • Comply with CE regulations

  • High mechanical strength housing,made by special flame retardant materials

LCTR_razem ZIELONE.png

LCTR Series CT 

Measuring range:30A ... 600A
<Accuracy Class>
LCTR 45/14:0.5, 1
LCTR 50/14:0.5, 1
LCTR 62/R:0.2, 0.5, 1

  • Secondary side optional 5A or 1A

  • IP20 protection board at the secondary side

  • Comply with CE regulations

  • High mechanical strength housing, made by  special flame retardant materials

LCTB_razem  ZIELONE.png

LCTB Series CT for both Busbar & cable 

Measuring range:30...7500A
Accuracy Class:0.2, 0.2S, 0.5, 1

  • Secondary side optional 5A or 1A

  • IP20 protection board at the secondary side

  • Comply with CE regulations

  • Suitable for Busbars

  • High mechanical strength housing, made by special flame retardant materials

LJ12_pom-2.png
LRC.png
LU01-(150)-web.png

For ND20CT Series

LRC Series

LU01

split core net.png

LCTS Series Split Core CT

Accuracy Class:0.2, 0.2S, 0.5, 1
Available sizes:23 x 33mm, 82 x 52mm, 
82 x 122mm, 82 x 162mm
Measuring range:100 ... 5000A

  • Secondary side optional 5A or 1A

  • IP20 protection board at the secondary side

  • Comply with CE regulations

  • Suitable for Busbars

  • High mechanical strength housing, made by special flame retardant materials

LE06_web.png
LCTP 3-Phase-CT-.png

LE, LW Series

LCTP Series

分流
B2 web.png

B2 60mV shunt

Measuring range:1A ... 18000A
Voltage output:60mV
<Accuracy Class>
0.2% when measuring range <2500A
0.5% when measuring range >2500A
External dimensions:Depends on size of current measurement range

  • Clamped to rail or base

  • Suitable for ammeters, power meters, electric or ferromagnetic counters and other instruments

 

Shunts

B2 web.png

B3 150mV shunt

Measuring range:1A ... 15000A
Voltage output:150mV
<Accuracy Class>
0.2% when measuring range <2500A
0.5% when measuring range >2500A
External dimensions:Depends on size of
current measurement range

  • Clamped to rail or base

  • Suitable for ammeters, power meters, electric or ferromagnetic counters and other instruments

B4 web.png

B4 50mV shunt

Measuring range:1A ... 15000A
Voltage output:50mV
<Accuracy Class>
0.2% when measuring range <2500A
0.5% when measuring range >2500A
External dimensions:Depends on size of current measurement range

  • Clamped to rail or base

  • Suitable for ammeters, power meters, electric or ferromagnetic counters and other instruments

B5 web.png

B5 75mV shunt

Measuring range:1A ... 15000A
Voltage output:75mV
<Accuracy Class>
0.2% when measuring range <2500A
0.5% when measuring range >2500A
External dimensions:Depends on size of current measurement range

  • Clamped to rail or base

  • Suitable for ammeters, power meters, electric or ferromagnetic counters and other instruments

三用電表
B6 web.png

B6 100mV shunt

Measuring range:1A ... 18000A
Voltage output:100mV
<Accuracy Class>
0.2% when measuring range <2500A
0.5% when measuring range >2500A
External dimensions:Depends on size of current measurement range

  • Clamped to rail or base

  • Suitable for ammeters, power meters, electric or ferromagnetic counters and other instruments

multimeters  / clamp meters / portable power analyzer

NP06-web.png

NP06 Digital multimeter

Volt. AC & DC:100μV...1000V
Current AC & DC:10μA...10.00A
Resistance:1Ω...40MΩ, zero correction
Capacitance:1pF ... 200.00μF, zero correction
Frequency:10.00 Hz ... 10MHz

  • Diode measurement and continuity test

  • Working period(%)

  • Measurement value retention function

  • Relative value measurement

  • Non-contact electrical voltage detection

NP08-web.png

NP08 Digital multimeter

Volt. AC & DC:100μV...1000V
Current AC & DC:10μA...10.00A
Resistance:1Ω...40MΩ, zero correction
Capacitance:1pF ... 200.00μF, zero correction
Frequency:
10.00 Hz ... 10MHz

  • Diode measurement and continuity test

  • Working period(%)

  • Measurement value retention function

  • Relative value measurementTemp. measurement with K-type thermocouple

  • Backlight function

NP10.png

NP10 Digital multimeter

Volt. AC & DC:100μV...1000V
Current AC & DC:10μA...10.00A
Resistance:1Ω...60MΩ, zero correction
Capacitance:1pF ... 40.00μF, zero correction
Frequency:10.00 Hz ... 10MHz

  • Diode measurement and continuity test

  • Working period(%)

  • Measurement value retention function

  • Relative value measurement

  • Temp. measurement from 0°C to 1300°C with K-type thermocouple

  • Peak measurement

NP15.png

NP15 True RMS digital multimeter 

Volt. AC & DC:1µV...1000V
Current AC & DC:1µA...10.00A
Resistance:10mΩ ... 40MΩ, zero correction
Capacitance:10pF...1000, zero correction
Frequency:6Hz...10MHz

  • Diode measurement and continuity test

  • Working period(%)

  • Analog signal 0-20mA / 4-20mA

  • Measurement value retention function

  • Relative value measurement

  • Built-in pulse signal generator

  • Low pass filter mode 1kHz

  • Support data recording and viewing functions (up to 32,000 readings)

  • Temperature measurement through J, K, Pt100, Pt1000 sensors

  • USB interface to connect to PC (optional)

  • Peak measurement, backlight function

NP15B-web.png

NP15B True RMS digital multimeter with Bluetooth

Volt. AC & DC:1µV...1000V
Current AC & DC:1µA...10.00A
Resistance:10mΩ ... 40MΩ, zero correction
Capacitance:10pF...1000, zero correction
Frequency:
6Hz...10MHz

  • Supports data recording and viewingfunctions (up to 32,000 readings)

  • Temperature measurement through J, K, Pt100, Pt1000 sensors

  • Diode measurement and continuity test

  • Working period(%)

  • Analog signal 0-20mA / 4-20mA

  • Measurement value retention function

  • Relative value measurement

  • Built-in pulse signal generator

NC11-web.png

NC11 AC Clamp-on meter

Current:400A or 1000A AC
Voltage:1000VAC

  • Temperature from 0 to 1300°C (K type thermocouple)

  • Backlit digital screen with analog indicator

  • Measurement value retention function

  • Automatic shut-down

  • Can compensate for wire resistance via REL key

  • Measuring functional diodes and transistors

  • Protection grade IP20

  • Press the Shift button for low impedance values, Compensation for low line resistance

NP40_1.png

NP40 Power Quality Analyzer

Event recording:dip, swell, overvoltage
Safety standards:EN 61010-1, CAT III 1000V / CAT IV 600V

  • 5,6" 320 x 240 pixel TFT full color screen

  • Real-time display of waveforms (4 voltages / 4 currents)

  • Half-cycle RMS measurements (voltage and current)

  • Measures TRMS current up to 3000A (using standard sensor)

  • Measurement of single-phase/3-phase power supplies (3-wire and 4-wire)

  • Measure voltage, current, harmonics, power, energy, surge current, flicker, etc.

  • Graphical display of waveform and vector data

  • 8-channel 16-bit AD converter, sampling frequency 20kS/s per channel

  • Power quality meets EN-50160 standard or user-defined limits

  • Built-in 8G TF card for data recording, which can record continuously from 2 hours to 7 days

  • Logging frequency ranges from 1 second to 60 minutes

  • Built-in Ethernet, branch remote operation, USB Host(Can save data and screenshots to external USB flash drive)

NP45_class-A.png

NP45 Power Quality Analyzer

Event recording:Dips, swells, overvoltages
Safety standards:EN 61010-1, CAT III 1000V / CAT IV 600V

  • 5,6" 640 x 480 pixel TFT full color screen

  • Real-time display of waveforms (4 voltages / 4 currents)

  • Half-cycle RMS measurements (voltage and current)

  • Measures TRMS current up to 6000A (with additional probe mode)

  • Measurement of single-phase/3-phase power supply (3-wire and 4-wire)

  • Measure voltage, current, harmonics, power, energy, surge current, flicker, etc.

  • Graphical display of waveform and vector data

  • 8-channel 16-bit AD converter, sampling frequency 163.84kS/s per channel

  • Power quality meets EN-50160 standard or user-defined limits

  • Built-in 32GB TF card for data recording, which can record continuously from 2 hours to 1 year

  • Logging frequency ranges from 1 second to 60 minutes

  • Built-in Ethernet, branch remote operation, USB Host(Can save data and screenshots to external USB flash drive)

NC12.png

NC12 AC/DC Clamp-on meter

Current:300A or 1000A AC/DC
Voltage:1000V AC/DC

  • Temperature from -200 to 800°C (Pt100 / Pt1000)

  • Backlit digital screen with analog indicator

  • Measurement value retention function

  • Maximum/minimum value recording function

  • Automatic shut-down

  • Can compensate for wire resistance via REL key

  • Measuring functional diodes and transistors

  • Protection grade IP20

  • You can press the Shift button to select low impedance values, low line resistance,Compensation of low capacitance values ​​or stray capacitance

NT10.png

NT10 Insulation meter

Voltage:30mV...1000VDC/VAC
Current:300μA...300mA DC/AC
Resistance:30Ω...30MΩ
Capacitance:30nF...30μF
Frequency:300Hz...100kHz
Temperature:-200...800ºC

  • Insulation resistance 3GΩ

  • Measure fill rate (%)

  • Pt100 / Pt1000

  • Measurement value retention function

  • Analog scale

NC14-web.png

NC14 AC/DC clamp-on meter

Current:400A or 1000A AC/DC
Voltage:1000V AC/DC

  • With/without power measurement KM

  • Power consumption measurement kWh, 49th harmonic

  • Phase angle measurement, THD measurement,DF measurement

  • Crest Factor / CF / Measurement

  • Power Factor / PF / Measurement

  • LPF mode

  • Backlit digital screen with analog indicator

  • Measurement value retention function

  • Maximum/minimum value recording function

  • Automatic shut-down

  • Can compensate for wire resistance via REL key

  • Measuring functional diodes and transistors

  • Protection grade IP20

  • You can press the Shift button to compensate for low impedance values, low line resistance, low capacitance values ​​or stray capacitance

bottom of page