Power network meters and analyzers
ND30
ND30IoT
-
63rd order odd harmonic, full color TFT LCD display
-
Built-in 8GB memory for data logging
L - L:100 to 690V
L - N: 57 to 400V
Current:1A/5A
Frequency:45-65Hz
Power supply:85...253VAC or 90...300VDC
-
Accuracy level 0.2S (IEC 62053-22)
-
THD, 63rd order odd harmonics
-
Built-in RTC, Web Server supports remote login
-
Support RS485 Modbus RTU, Ethernet communica tion port, MODBUS TCP/IP, HTTP, FTP, MQTT / Relay output x 2
-
Optional Pt100 or DI input x2, 4-20mA output x1
-
Optional PROFITNET or BACnet Version
NMID30-1 / 2 Three-phase VAR hour meter
Built-in 100A CT, effectively saving space and cost.
Line voltage:173 to 500V
Phase voltage:100 to 289V
Current:1A / 5A or built-in 100A CT Frequency:45-65Hz
Power supply:87...275VAC ±10% or 120....380VDC ±20%
<Power Factor>
Forward / Reverse / Total Active Power:
0 to 9999999.9 kWh
Forward / Reverse / Total Reactive Power:
0 to 9999999.9 kVArh
-
Supports RS485 Modbus RTU, two sets of PWM outputs
ND25 Power Meter
Directly replace PM5350
L - L:100 to 600V
L - N:57.5 to 346.42V
Current:1A/5A
Frequency:45-66Hz
Power supply:100-550VAC / VDC
-
Accuracy class 0.2S (IEC 62053-22)
-
THD, 31st odd harmonics
-
Built-in RTC
-
Support RS485 Modbus RTU, PWM output x 2
-
Optional 8MB memory for data recording
-
Optional Ethernet Version
ND45
-
Class A ultra-high accuracy
-
Frequency measurement error can reach ±0.010 Hz
★Comply with IEC EN 50160 and IEC 61000-4-30 standards
★Record measurement values before and after dips and surges
★Supports IEC 60870-5-104 communication protocol (optional)
★Supports external GPS module - STR receiver for time synchronization (Optional)
Voltage:69.3 / 120V, 57.7 / 100V or 230 / 400V
Current:1A / 5A
Frequency:42.5-69Hz
-
Measure more than 500 power quality parameters,4 quadrants of electricity
-
Record measurement values before and after the event occurs,Monitor 6 external meters through PWM output
-
5.6” full-color TFT touch screen
-
Built-in RTC, supports synchronization with time server
-
Supports up to 32GB SD card for data recording,RS485 Modbus RTU,Ethernet and USB2.0 communication port, Modbus TCP/IP,Web server, FTP Server, DHCP client
-
Optional input-Pt100 / Pt1000, binary
-
Optional output-binary, analog, Relay
NS5
Designed for applications where
generators are connected to the gridVoltage:50...150V or 150...400V
Voltage difference:δU -20..0..20%
Frequency:45-65Hz
Frequency difference:δf -10..0..10 %
Phase shift:φ0..360°
Power supply:85...253VAC or 90...300VDC
-
Two sets of control signals 20...250VAC/DC
-
Lock synchronization x 1, start synchroniza tion x 1
-
Two sets of NO contact outputs
-
0.2 Class high accuracy
-
3.5” full color TFT screen
-
Support RS485 Modbus RTU,Ethernet communication port, Web server,
Modbus TCP / IP、DHCP server
NF20
Designed for capacitor bank applications Voltage: 30 to 550VAC (L-L / L-N)
Current: 1A / 5A
Frequency: 40-70Hz
Power supply: 110 to 550 VAC/DC
-
31 odd-order harmonic steps
-
Four-quadrant operation of capacitors
-
0.5 Class high accuracy
-
Monitors power values of individual capacitors
-
Programmable connection / disconnection and discharge times, independent kvar value for capacitor banks
-
Supports 4, 6, or 8 relay outputs, RS485 Modbus RTU
N27P 1-phase Power Meter
-
OLED display
-
Built-in RS485 MODBUS RTU, OLED graphic display
★Parameter settings can be performed through free eCon software (via USB
Voltage:0...100/400VAC
Current:1A/5A via CT or 63A direct measurement
Output:Relay output x 2 or Relay x1 +
4...20mA x 1 outputs
External dimensions:53 x 110 x 60mm
SPC5 Reverse power controller
-
Special for solar power grid, can control inverter output
-
For three-phase four-wire power grid
★Dual RS485 communication port (Master+ Slave)
Measured voltage:100VLL to 600VLL (57.7VLN to 346.4VLN)
Current input:1A / 5A
Power supply:100V to 550VAC / DC
Operating temperature:-20 to +70 °C
-
Display the power flow between the inverter, grid and load
-
Accuracy Class 0.2S (IEC 62053-22)
NR30IoT Power Meter
-
63rd order odd harmonic, built-in 63A CT
-
Built-in 8GB memory for data logging function
L - L:100 to 690V
L - N:57 to 400V
Current:1A/5A or built-in 63A CT
Frequency:45-65Hz
Power supply:85...253VAC or 90...300VDC
-
Support RS485 Modbus RTU, Ethernet communication port, MODBUS TCP/IP, HTTP, FTP, MQTT, Relay output x 2
-
Accuracy level 0.2S (IEC 62053-22)
-
THD, 63rd order odd harmonics
-
0.2 Class high accuracy
-
Built-in RTC
-
Optional PROFITNET or BACnet Version
Digital Meters
N24 Digital Display
Power: 85 ... 253 V a.c./d.c.
Protection level: IP65
<Input Signal>
N24S: 0-20mA / 4-20mA / ± 20mA ± 60 mV / 0-10 V / ±10 V
N24T: Pt100 -50-150°C / -50-400°C Thermocouple J / K
N24Z: 0-100 / 0-250 / 0-400VAC, 0-1A / 0-5A AC
Frequency: 20-500 Hz
N24H: ±100 / 250 / 400VDC, 0-100/200VDC, ± 1 / 5 A d.c.
-
4-digit LED display
-
Parameters can be set via PD14 programmer and free eCon software download
-
Automatically or manually compensates for cold junction temperature or wire resistance measured by Pt100 sensor
N25 Digital Display
Power: 85 ... 253 V a.c./d.c.
Protection level: IP65
<Input Signal>
N25S:0-20mA / 4-20mA / ± 20mA ± 60 mV / 0-10 V / ±10 V
N25T: Pt100 -50-150°C / -50-400°C Thermocouple J / K
N25Z:0-100 / 0-250 / 0-400VAC, 0-1A / 0-5A AC
Frequency: 20-500 Hz
N25H: ±100 / 250 / 400VDC, 0-100/200VDC, ± 1 / 5 A d.c.
-
5-digit LED display
-
Parameters can be set via PD14 programmer and free eCon software download
-
Automatically or manually compensates for cold junction temperature or wire resistance measured by Pt100 sensor
N30x multi-function monitor
Three-color LED, RS485, 4 groups of alarms, can be used as secondary output
<Input signal>
N30H:DC ±100V/500V, ±1/5A
N30P: AC 0-1A/5A, 0-100/400V
N30U:Pt100, Pt500, Pt1000, J, K, N, E, R, S,
0-400Ω, 0-4kΩ, ±60mV, ±10V, ±20mA
N30O:pulse wave -10kHz/8kHz,encoder-10kHz
frequency -100kHz/1MkHz,Speed-100kHz,
<Optional output>
-RS485 MODBUS RTU
- 0/4-20mA x 1 & 0-10VDC x 1
- OC type NPN (N30P)
- 24VDC/30mA power output (N30U/N30O)
Power supply:85-253VAC/DC, 20-40VAC/DC
-
Alarm output:2 NO relays and 2 CO relay outputs
-
3-color LED red/orange/green (5 digits, character height 14mm), Different intervals can be distinguished, and the values are displayed in different colors.
-
Support RS485 MODBUS RTU
-
Front panel IP65 protection
N32x multi-function display
High contrast LCD, RS485, 4 groups of alarms, can be used as secondary output
<Input signal>
N32H:DC ±50...±600V, ±75...±1500mV
N32P:AC 0-1A/5A, 0-100/230/400V
N32U:Pt100, Pt500, Pt1000, J, K, N, E, R, S
0-400Ω, 0-4kΩ, ±60/150/300mV, ±10V,
±20mA, 4...20mA
N32O:pulse wave -10kHz/8kHz, encoder-10kHz
frequency -100kHz/1MkHz,Speed-100kHz
<Optional output>
- 0/4-20mA x 1 & 0-10VDC x 1
- OC type NPN (N30P/N30H)
- 24VDC/30mA power output (N30U/N30O)
Power supply:85-253 VAC/DC, 20-40 VAC/DC
Alarm output:1 NO relay, 3 CO relay outputs
-
High contrast and built-in backlight two-line LCD display that can be used simultaneously display measured value, time, uncalculated quantity, unit
-
Front panel IP65 protection
N21 strip display
Can be displayed horizontally or vertically
Voltage input:±75mV/±10V
Current input:±20mA
Pt100:-200 to 850°C
Thermocouple J:-50 to 1200°C
Thermocouple K:-50 to 1370°C
Power supply voltage:24-230VAC/DC
-
Provide 24VDC power supply to the sensor
-
A set of alarm outputs
-
OLED strip graphic display(horizontal or vertical)
-
Front panel IP65 protection
NA5PLUS / NA6PLUS digital display
High-end graphic display with mathematical operation function
<Programmable input>
Voltage:0-600V/±75mV, ±300mV
Current:±40mA/±5A
<temperature>
RTD:Pt100/Pt500/Pt1000
TC:J/K/N/E/R/S/T
Resistance:0-10kΩ
<Analog output>
- 0/4-20mA x 2
- 0-10VDC x 2
- 0/4-20mA x 1
- 0-10VDC x 1
Optional output 4 relays or 8 OC type outputs
Power supply:95-230VAC/DC or 20-24VAC/DC
NA5PLUS:1 set of input, 1 set of bar graph
and Digital Display
NA6PLUS:2 sets of inputs, 2 sets of bar graphs
and Digital Display
-
Multi-color bar graphic programmable display
-
Support RS485 MODBUS RTU
Transducer
Input: programmablPt100/250/500
1000, J, K, S, N,0/4...20, ±20 mA, 0...5/10,
±5, ±10 V, ±60, ±150 mV,0...400Ω/4000Ω
Output: 0/4...20 mA or 0...10 V
-
IP40
-
free eCon software (using PD14
programmer)
P30H
Suitable for charging pile / Energy storage
3-year warranty
Built-in:LCD display screen, can display 8 characters x two lines
Voltage:0 ... 12 / 48 / 100 / 250V (direct measurement) / 0...600 / 1000V (via D5 high voltage module)
Current:Shunt +/- 150mV
Output:0/4…20mA x 1, Relay x 2
Power supply:85-253Vac/85-300Vdc
Dimensions:45 x 120 x 100mm
-
Accuracy 0.2%
-
Built-in RS485 Modbus-RTU Protocol, 4MB memory, can record 534336 pieces of data
-
Optional Ethernet Modbus TCP/IP, Support HTTP, FTP, Web server, ftp server, clientDHCP
-
Din rail installation
-
IP20
P30O
Input-2 programmable inputs:
pulse counter, frequency,rotational speed, period, operating time counter,
pulse differential counter on inputs
or encoder
Output: 1 x analog 0/4...20 mA or 0...10 V
1 x relay NO,1 x relay NO or 24V/30mA,
output (optional output 2)
-
RS-485 Modbus (Slave or Master)
-
Ethernet 10/100 Base-T(option)
-
LCD 2x8 characters with backlight
-
IP40
-
Alarms indicated on the display
-
Internal memory 534336 samples
-
WWW server, FTP, Modbus TCP/IP Slave (optionally)
-
Data logging in internal memory or
on SD card (optionally)
P30P
Input:1-phase power network,fixed 1A (X/1A), 5A (X/5A),100 V(x/100 V) or 250 V
Output:1 x analog 0/4...20 mA or 0...10 V,
1 x relay NO or 0/4...20 mA or0...10 V (optional output 2),1 x relay NO or 24V/30mA,output (optional output 3)
-
RS-485 Modbus (Slave or Master)
-
Ethernet 10/100 Base-T(option)
-
LCD 2x8 characters with backlight
-
IP40
-
Alarms indicated on the display
-
Internal memory 534336 samples
-
WWW server, FTP, Modbus TCP/IPSlave (optionally)
-
Data logging in internal memory or on SD card (optionally)
P30U
Input:programmable,Pt100/250/500/1000,
Cu100, Ni100, Ni1000,J, K, N, E, R, S, T, B
0...4/20, ±20 mA,-5...20, ±75, ±200 mV,
±10 V, ±24 V,400Ω, 2000Ω, 5500Ω,
RS-485 Master or Slave
Output: 1 x analog 0/4...20 mA or 0...10 V,
1 x relay NO,1 x relay NO or 24V/30mA ,
output (optional output 2)
-
RS-485 Modbus (Slave or Master)
-
Ethernet 10/100 Base-T(option)
-
LCD 2x8 characters with backlight
-
IP40
-
Alarms indicated on the display
-
Internal memory 534336 samples
-
WWW server, FTP, Modbus TCP/IPSlave (optionally)
-
Data logging in internal memory or on SD card (optionally)
T22CT / T23CT
AC/DC current converter
<T22CT AC current sensor>
Output:4...20mA or 0...20mA DC
<Measurement range>
- 50...300A (T22CT-1)
- 150...750A (T22CT-2)
Supply voltage:24VDC
<T23CT AC / DC current sensor>
Supply voltage:24VDC
Measuring range:50A...300A
Output:4...20mA
-
Support DIN rail installation
Temperature and Humidity Transducer
18S temp. & humidity Transducer
Suitable for semiconductor equipment and
environmental control applications
Measuring range:-30°C to +80°C, 0 to 100% humidity
Output:RS485 Modbus RTU
Protection level:IP65
-
Temperature and humidity 2-in-1 sensor
-
Calculation of selected physical quantities (dew point temperature / absolute humidity)
-
Convert measured values into output signals based on individual linear characteristics
-
Store the max and min of measurement and calculated values, and program measurement average time
P18 / P18D temp. & humidity Transducer
-
Suitable for applications such as machinery and equipment
-
The wires can be assembled according to the requirements before shipment
Measuring range:-40°C to +85°C, 0 to 100% humidity
Output:None, 0-10V x 2, 4-20mA x 2, RS485 Modbus RTU
Protection level:IP65
-
Temperature and humidity 2-in-1 sensor
-
Calculation of selected physical quantities (dew point temperature / absolute humidity)
-
Convert measured values into output signals based on individual linear characteristics
-
Store the max and min of measurement and calculated values, and program measurement average time
ULT20/21 Ultrasonic Level Sensor
<Level Measurement Range>
ULT20: 0.5...8M
ULT21: 0.5...10M / 15M
Ultrasonic Frequency: 50KHz
Measurement Resolution: 0.001m, ±1% measurement range error
Power Supply: 24VDC
Analog Output: 0 / 4..20 mA
-
Supports RS-485 Modbus RTU
-
Built-in 2 alarm relay outputs, data setting memory
-
Automatic temperature compensation for calculating fill level in tanks or flow in open channels
-
IP66 or IP68 protection level
HT20
Measuring:temperature, relative humidity absolute humidity, dew point
Measurement range: -30 ... or 0...100% RH,
-20 ... 60 ... 85°C
Output: Modbus TCP/IP
Interface:Ethernet (WWW, FTP, SMTP, DHCP)
-
LCD, 2 x 16 characters
-
Supply Voltage:6 V d.c. or PoE IEEE 802.3af - option
-
Built-in 8GB internal memory
-
IP20
HT20IoT
Measuring:temperature, relative humidity absolute humidity, dew point
Measurement range:-30 ... or 0...100% RH,
-20 ... 60 ... 85°C
Output: Modbus TCP/IP
-
Interface:Ethernet (WWW, FTP, SMTP, DHCP) MQTT Protocol
-
LCD, 2 x 16 characters
-
Output: Modbus TCP/IP
-
Supply Voltage: 6 V d.c. or PoE IEEE 802.3af - option
-
Built-in 8GB internal memory
-
IP20
HT22IoT environmental parameter monitor
Suitable for greenhouses, clean rooms, laboratories...
Measuring range:-20°C to +60°C, 0 to 95% humidity
Lux:0...60000lux
TVOC:0...60000ppb
CO2:400...60000ppm
<Measure, monitor and record the following environmental parameters>
- Temperature, humidity, illumination, CO2 concentration
- TVOC (total volatile organic compounds in the air)
-
Actively notify whether the measured value exceeds the limit range, and DO Alarm can be set for the selected input value
-
Built-in 8GB memory for data recording
-
Built-in RS-485 Modbus RTU, Ethernet 10/100 BASE-T
-
Support Modbus TCP/IP, HTTP, FTP, www, ftp, DHCP, SMTP, MQTT
-
Support RTC
KD6 Recorder
Compact Recorder
Input:Up to 8 sets of universal analog inputs, 8 sets of binary inputs
Output:up to 12 groups of relay outputs, 8 groups of analog outputs
Power supply:85...253VAC, 90...300VAC, 20...60VDC
Communication port:RS-485 MODBUS (master-slave), ETHERNET MODBUS TCP/IP, WWW, FTP, NTP, DHCP, USB Host 2.0
Dimensions:96 x 96 x 77mm
-
3.5" TFT full color LCD display
-
Up to 60 logic channels
-
Up to 8 analog channels
-
Support 24Vd.c./30mA power output
-
Parameter setting and data transmission can be performed through the USB port
-
Built-in 8GB memory
-
Advanced mathematical function operations
Data Logger
KD7 Recorder
FDA certified full-featured recorder 3-year warranty
Communication Interfaces:RS-232, RS-485 (master-slave),USB, ETHERNET MODBUS TCP/IP, WWW/FTP Server
PC software:KD7 SETUP, KD CHECK, KD CONNECT, KD archive
Dimensions:144 x 144 x 155mm
-
Display curve charts, bar trend charts, pie charts, digital and analog indicators
-
Each channel can have settings assigned to color, name, range and presentation view
-
Support data statistics
-
12 analog inputs (programmable and standard)
-
5.7” LCD TFT touch panel
-
6 or 32 Alarm outputs
-
8 or 16 DIs
-
4 or 8 analog outputs
-
Built-in 6MB memory
-
Data can be recorded on external CF card
-
Supports CF card with a maximum capacity of 4 GB
-
IP65 protection rating on front panel
-
Up to 24 measurement channels
-
MS Windows®CE operating system
FDA certified economical recorder with
3-year warranty
Supports communication via: RS-485, USB MSWindows®CE operating system
PC software: KD7 SETUP, KD CHECK, KD CONNECT, KD ARCHIVE External dimensions: 144 x 144 x 155mm
-
5.7" LCD TFT touch panel
-
Displays trend graphs, bar graphs, digital and analog indicators
-
Supports data statistics
-
Each channel can assign settings for color, name, range, and demo view
-
Built-in 6MB memory
-
Data can be recorded on external CF cards
-
Supports CF cards up to 4 GB capacity
-
IP65 protection level on front panel • Up to 6 measurement channels
-
6 analog inputs (programmable and standard)
-
6 or 12 alarm outputs
-
8 or 16 DI
Interface Converters / Gateways
PD9
RS485 to Ethernet interface converter
Communication port:RS485 x 1,
Ethernet WAN / LAN x 1
Working mode:TCP / UDP Server & Client
Supply voltage:5...36VDC
Operating temp:-40 to 85°C
-
Easy settings via webpage or setting software
-
Miniaturized, DIN rail mounting design
-
Support Modbus RTU to TCP, Modbus Polling,DHCP, dynamic or static IP
-
Watchdog function
-
Firmware upgradeable via network
PD9W
RS485 to WiFi interface converter
Comm. protocol:Modbus RTU / Modbus TCP IP
Support:TCP Server, TCP Client, UDP Client,UDP Server
Comm. port:802.11b/g/n WiFi, RS485 x 1,
RS232 x 1, Ethernet WAN / LAN x 1
Working mode:TCP/UDP Server & Client
Electrostatic protection:15/8 kV
Power supply voltage:5...36V
Operating temp:-40 to 85°C
-
Easy settings via web page or setting software
-
Support DHCP support, dynamic or static IP
-
Support STA/AP/AP+STA mode
-
Support virtual COM Port
-
Watchdog function
PD20
USB to RS-485 interface converter
-
Compatible with standard USB 1.1 and USB 2.0
-
RS-485 maximum baud rate 115.2kbps
-
USB port maximum transfer rate up to 1Mb/s (depending on RS-485 cable length)
-
Support virtual COM Port
-
Bidirectional data transmission (half-duplex)
-
Designed with galvanic isolation protection and powered directly by USB
USB to RS-232(TTL) interface converter
-
Compatible with standard USB 1.1 and USB 2.0
-
RS-232 maximum baud rate 115.2kbps
-
Support virtual COM Port
-
Kit includes 1.5m profile with RJ12 plugTransmission line for setting up LUMEL products
-
Designed with galvanic isolation protection and powered directly by USB
Temperature Controllers
RE11
European quality, domestic price, 3-year warranty
<Accuracy>
J, K, T input:0.25% ± 1° of F.S.
R, S input:0.5% of F.S. ±2° (preheating time: 20 minutes)
RTD input:0.1% of F.S ±1°
Resolution:0.1/1° for TC/RTD (R and STC are fixed at 1°)
Control output:relay / SSR
Auxiliary output:relay
Control mode:automatic adjustment /
self-adjustment / PID / ON-OFF
Supply voltage:85 to 270VAC/VDC
Dimensions:52 x 52 x 76mm
-
4 + 4 digit LED dual display
RE62
DIN rail installation, OLED display
Input:NTC J, K, RTD Pt100, ±20mA,±60 mV, ±10V
Output optional:relay x 3, relay x 2 + SSR x 1,Relay x 2 + 4...20mA x 1
Universal power supply:22 V a.c./d.c. or 230 V a.c./d.c.
Dimensions:53 x 110 x 60.5mm
-
128 * 64 pixel OLED display
-
Built-in RS485 MODBUS-RTU
-
Parameters can be set through eCon software
-
SMART PID algorithm
-
DIN rail installation
RE72
Input:programmable Pt100/1000,J, T, K, S, R, B, E, N, L or0/4...20 mA, 0...5/10 V
Additional Input:logic, CT Input, 0/4... 20 mA (option)
Output: 2 x relays, logic 0/5 V, 0/4...20mA,
0...10 V, supplying output,24 VDC / 30 mA (Option)
Interface:RS-485 Modbus
-
On/Off , PID, heating or cooling
-
Red & Green LED 2 x 4 digits
-
Supply Voltage:85...253 V a.c./ d.or
20...40 V a.c./d.c
-
IP65
-
Soft start / 6 types of alarms /alarm LATCH function
RE82
Input:programmable Pt100/1000, J, T, K, S, R, B, E, N, L or 0/4...20 mA, 0...5/10 V
Additional Input: 2 x logic, CT Input,
0/4... 20 mA (option)
Output: 2 x relays and 2 x relays,logic 0/5V, 0/4...20 mA, 0...10 V (option), supplying output 24 V d.c. 30 mA(option)
Interface:RS-485 Modbus
-
On/Off , PID, heating or cooling
-
Red & Green LED 2 x 4 digits 2 bargraphs
-
Supply Voltage:85...253 V a.c./ d.c or 20...40 V a.c./d.c
-
IP65
-
Soft start / 6 types of alarms /alarm LATCH function
RE92
Dual temperature control loops, dual communications, LCD display
Two sets of universal inputs:RTD, TC, 0..5/10V, 0/4..20mA,
One set of 0/4..20mA or 0..5/10V input
<Output>
- 6 groups of relays or 4 groups of relays + 2 groups of SSR output
- 3 sets of binary outputs
- 1 set of 0/4-20mA x 1 or 0-10VDC output
Built-in:RS-485 Modbus RTU Master & Slave,Ethernet (MODBUS TCP Slave, FTP & Web server)
Power supply voltage:85...253VAC/DC
Dimensions:96 x 96 x 100mm
-
Double loop temperature controller
-
Can independently control two controlled objects or control two physical values in one object
-
SMART PID algorithm with self-tuning function, on/off, three-stage control heating and cooling and step-by-step control, 320 x 240 pixel 3.5" LCD display, data logging function, support for .CSV files, SD memory card self-update and data saving
-
Parameters can be set through eCon software (via USB port)
I/O Modules
SM4 / SM5 digital output module
SM4:8 OC outputs or 4 Relay outputs
SM5:8 digital inputs
<Support>
- RS-232 (RJ connector, for parameter setting)
- RS-485 MODBUS RTU & ASCII
-
Can be Confirgued by eCon software
<4 programmable analog inputs>
±10 V, ± 20mA, Pt100, Pt500,Pt1000, J, k, S,
±150mV
<Support>
- RS-485 Modbus Salve
- Two programmable alarm outputs
- Mathematical functions: addition,
subtraction,multiplication,division, average,
minimum,maximum
-
Two virtual measurement channels to
-
perform mathematical functions on the
-
channel or between measurement
-
channels, programmable operating time
-
counter
-
Parameter setting via USB port, no need
to connect to the power supply
S4AO analog output module
<4 sets of analog output>
- 4 x 0/4...20mA
- 4 x 0..10V
- 2 x 0/4...20mA
- 2 x 0...10V
Support:RS-485 Modbus Master & Salve
- Master Modbus function dedicated to read
out data from other RS-485 devices and to scale analog value.
- Slave Modbus function to set the signal on
analog outputs.
-
Output work time counter for values above and below a certain threshold.
-
Parameter setting via USB port, no need to connect to the power supply
Analog Panel Meters
Moving-iron meters
3 Phase Meters
Moving-Coil meters
Max demand ammeter
Power factor and
frequency meters
Dual Meters
Current Transformer
LCTS compact Series Split Core CT
<Measurement ranges>
LCTS 50/18SC type:100 250A
LCTs 50/32SC type:250 500A
Accuracy Class:1
-
Secondary side optional 5A or 1A
-
IP20 protection board at the secondary side
-
Comply with CE regulations
-
High mechanical strength housing,made by special flame retardant materials
For ND20CT Series
LRC Series
LU01
LCTS Series Split Core CT
Accuracy Class:0.2, 0.2S, 0.5, 1
Available sizes:23 x 33mm, 82 x 52mm,
82 x 122mm, 82 x 162mm
Measuring range:100 ... 5000A
-
Secondary side optional 5A or 1A
-
IP20 protection board at the secondary side
-
Comply with CE regulations
-
Suitable for Busbars
-
High mechanical strength housing, made by special flame retardant materials
LE, LW Series
LCTP Series
B2 60mV shunt
Measuring range:1A ... 18000A
Voltage output:60mV
<Accuracy Class>
0.2% when measuring range <2500A
0.5% when measuring range >2500A
External dimensions:Depends on size of current measurement range
-
Clamped to rail or base
-
Suitable for ammeters, power meters, electric or ferromagnetic counters and other instruments
Shunts
B3 150mV shunt
Measuring range:1A ... 15000A
Voltage output:150mV
<Accuracy Class>
0.2% when measuring range <2500A
0.5% when measuring range >2500A
External dimensions:Depends on size of
current measurement range
-
Clamped to rail or base
-
Suitable for ammeters, power meters, electric or ferromagnetic counters and other instruments
B4 50mV shunt
Measuring range:1A ... 15000A
Voltage output:50mV
<Accuracy Class>
0.2% when measuring range <2500A
0.5% when measuring range >2500A
External dimensions:Depends on size of current measurement range
-
Clamped to rail or base
-
Suitable for ammeters, power meters, electric or ferromagnetic counters and other instruments
B5 75mV shunt
Measuring range:1A ... 15000A
Voltage output:75mV
<Accuracy Class>
0.2% when measuring range <2500A
0.5% when measuring range >2500A
External dimensions:Depends on size of current measurement range
-
Clamped to rail or base
-
Suitable for ammeters, power meters, electric or ferromagnetic counters and other instruments
B6 100mV shunt
Measuring range:1A ... 18000A
Voltage output:100mV
<Accuracy Class>
0.2% when measuring range <2500A
0.5% when measuring range >2500A
External dimensions:Depends on size of current measurement range
-
Clamped to rail or base
-
Suitable for ammeters, power meters, electric or ferromagnetic counters and other instruments
multimeters / clamp meters / portable power analyzer
NP06 Digital multimeter
Volt. AC & DC:100μV...1000V
Current AC & DC:10μA...10.00A
Resistance:1Ω...40MΩ, zero correction
Capacitance:1pF ... 200.00μF, zero correction
Frequency:10.00 Hz ... 10MHz
-
Diode measurement and continuity test
-
Working period(%)
-
Measurement value retention function
-
Relative value measurement
-
Non-contact electrical voltage detection
NP08 Digital multimeter
Volt. AC & DC:100μV...1000V
Current AC & DC:10μA...10.00A
Resistance:1Ω...40MΩ, zero correction
Capacitance:1pF ... 200.00μF, zero correction
Frequency:10.00 Hz ... 10MHz
-
Diode measurement and continuity test
-
Working period(%)
-
Measurement value retention function
-
Relative value measurementTemp. measurement with K-type thermocouple
-
Backlight function
NP10 Digital multimeter
Volt. AC & DC:100μV...1000V
Current AC & DC:10μA...10.00A
Resistance:1Ω...60MΩ, zero correction
Capacitance:1pF ... 40.00μF, zero correction
Frequency:10.00 Hz ... 10MHz
-
Diode measurement and continuity test
-
Working period(%)
-
Measurement value retention function
-
Relative value measurement
-
Temp. measurement from 0°C to 1300°C with K-type thermocouple
-
Peak measurement
NP15 True RMS digital multimeter
Volt. AC & DC:1µV...1000V
Current AC & DC:1µA...10.00A
Resistance:10mΩ ... 40MΩ, zero correction
Capacitance:10pF...1000, zero correction
Frequency:6Hz...10MHz
-
Diode measurement and continuity test
-
Working period(%)
-
Analog signal 0-20mA / 4-20mA
-
Measurement value retention function
-
Relative value measurement
-
Built-in pulse signal generator
-
Low pass filter mode 1kHz
-
Support data recording and viewing functions (up to 32,000 readings)
-
Temperature measurement through J, K, Pt100, Pt1000 sensors
-
USB interface to connect to PC (optional)
-
Peak measurement, backlight function
NP15B True RMS digital multimeter with Bluetooth
Volt. AC & DC:1µV...1000V
Current AC & DC:1µA...10.00A
Resistance:10mΩ ... 40MΩ, zero correction
Capacitance:10pF...1000, zero correction
Frequency:6Hz...10MHz
-
Supports data recording and viewingfunctions (up to 32,000 readings)
-
Temperature measurement through J, K, Pt100, Pt1000 sensors
-
Diode measurement and continuity test
-
Working period(%)
-
Analog signal 0-20mA / 4-20mA
-
Measurement value retention function
-
Relative value measurement
-
Built-in pulse signal generator
NC11 AC Clamp-on meter
Current:400A or 1000A AC
Voltage:1000VAC
-
Temperature from 0 to 1300°C (K type thermocouple)
-
Backlit digital screen with analog indicator
-
Measurement value retention function
-
Automatic shut-down
-
Can compensate for wire resistance via REL key
-
Measuring functional diodes and transistors
-
Protection grade IP20
-
Press the Shift button for low impedance values, Compensation for low line resistance
NP40 Power Quality Analyzer
Event recording:dip, swell, overvoltage
Safety standards:EN 61010-1, CAT III 1000V / CAT IV 600V
-
5,6" 320 x 240 pixel TFT full color screen
-
Real-time display of waveforms (4 voltages / 4 currents)
-
Half-cycle RMS measurements (voltage and current)
-
Measures TRMS current up to 3000A (using standard sensor)
-
Measurement of single-phase/3-phase power supplies (3-wire and 4-wire)
-
Measure voltage, current, harmonics, power, energy, surge current, flicker, etc.
-
Graphical display of waveform and vector data
-
8-channel 16-bit AD converter, sampling frequency 20kS/s per channel
-
Power quality meets EN-50160 standard or user-defined limits
-
Built-in 8G TF card for data recording, which can record continuously from 2 hours to 7 days
-
Logging frequency ranges from 1 second to 60 minutes
-
Built-in Ethernet, branch remote operation, USB Host(Can save data and screenshots to external USB flash drive)
NP45 Power Quality Analyzer
Event recording:Dips, swells, overvoltages
Safety standards:EN 61010-1, CAT III 1000V / CAT IV 600V
-
5,6" 640 x 480 pixel TFT full color screen
-
Real-time display of waveforms (4 voltages / 4 currents)
-
Half-cycle RMS measurements (voltage and current)
-
Measures TRMS current up to 6000A (with additional probe mode)
-
Measurement of single-phase/3-phase power supply (3-wire and 4-wire)
-
Measure voltage, current, harmonics, power, energy, surge current, flicker, etc.
-
Graphical display of waveform and vector data
-
8-channel 16-bit AD converter, sampling frequency 163.84kS/s per channel
-
Power quality meets EN-50160 standard or user-defined limits
-
Built-in 32GB TF card for data recording, which can record continuously from 2 hours to 1 year
-
Logging frequency ranges from 1 second to 60 minutes
-
Built-in Ethernet, branch remote operation, USB Host(Can save data and screenshots to external USB flash drive)
NC12 AC/DC Clamp-on meter
Current:300A or 1000A AC/DC
Voltage:1000V AC/DC
-
Temperature from -200 to 800°C (Pt100 / Pt1000)
-
Backlit digital screen with analog indicator
-
Measurement value retention function
-
Maximum/minimum value recording function
-
Automatic shut-down
-
Can compensate for wire resistance via REL key
-
Measuring functional diodes and transistors
-
Protection grade IP20
-
You can press the Shift button to select low impedance values, low line resistance,Compensation of low capacitance values or stray capacitance
NC14 AC/DC clamp-on meter
Current:400A or 1000A AC/DC
Voltage:1000V AC/DC
-
With/without power measurement KM
-
Power consumption measurement kWh, 49th harmonic
-
Phase angle measurement, THD measurement,DF measurement
-
Crest Factor / CF / Measurement
-
Power Factor / PF / Measurement
-
LPF mode
-
Backlit digital screen with analog indicator
-
Measurement value retention function
-
Maximum/minimum value recording function
-
Automatic shut-down
-
Can compensate for wire resistance via REL key
-
Measuring functional diodes and transistors
-
Protection grade IP20
-
You can press the Shift button to compensate for low impedance values, low line resistance, low capacitance values or stray capacitance